IPG Product Lineup & Fixed Pricing

IPG Independent Power Generators

Explore our standardized lineup of 15 IPG Independent Power Generator models engineered from 5 kW to 100 kW. Review electrical specifications, evaluate sizing criteria, and inspect fixed unit pricing across the entire product family.

IPG Independent Power Generator Systems - Category Overview
IPG Independent Power Generator Series Standardized Range: 5 kW – 100 kW
Available Capacities & Pricing

Choose Your Generator

Explore our available capacities and find the right generator for your needs.

Product images are samples for illustration purposes. Actual appearance and specifications may vary. All models follow the same operating principle, although their capacities and specifications differ.
Local currency prices are indicative conversions from EUR using the latest available published exchange rate. Final invoice and payment amounts will be confirmed by IPG.
Interactive Sizing Tool

Calculate Your Power Requirements

Select the appliances and equipment you intend to power. Enter their actual power ratings to estimate your total electricity requirements and identify a suitable generator capacity.

Appliance Rating Guidance: Appliance power consumption varies by model and size. Check the manufacturer's rating plate or product manual before entering the wattage. Not sure about your appliance wattage? Check its rating label or user manual. You can also contact our sales team for assistance.

Configured Equipment & Appliances

Specify continuous running wattage and motor surge requirements below.

Engineering Parameters & Startup Assumptions

Initial planning estimate applied to running load. Does not double-count starting surge headroom.
Calculated Assessment

Your Estimated Power Requirements

Calculated demand based on entered nameplate continuous ratings, motor startup headroom, and engineering reserve margins.

Total Running Load
0 W (0.00 kW)
Sum of continuous running wattage
Motor Startup Surge
+0 W (+0.00 kW)
Staggered startup (largest single motor surge)
Engineering Reserve
+0 W (20% margin)
Continuous capacity buffer for stability
Estimated Generator Capacity
0.0 kW
Minimum recommended generator rating
Generator Sizing Guidance

Indicative IPG Capacity Options

The standardized IPG product family offers 15 fixed capacities from 5 kW to 100 kW. Below are models meeting or exceeding your calculated requirement:

Important Technical Sizing & Capacity Comparison Notice
  • Indicative Capacity Comparison: This calculation provides an initial sizing estimate based on user-entered appliance figures. It does not constitute a guaranteed electrical engineering design or warranty of operational compatibility.
  • Provisional Ratings: IPG generator specifications and rated outputs represent preliminary design parameters and have not all been independently verified by accredited third-party laboratories. They should not be interpreted as manufacturer-guaranteed performance under all operating conditions.
  • Operating Parameter Dependencies: Real-world equipment operation depends on verified continuous kilowatt output, momentary motor-starting surge capability (kVA), single-phase vs. three-phase balancing, operating voltage tolerances, and actual load power factor (&cos;φ).
  • Pre-Purchase Engineering Consultation: Customers are strongly advised to consult with the IPG sales engineering desk to review electrical single-line diagrams, motor locked-rotor amps (LRA), and duty cycle expectations prior to placing an order.
Procurement & Orders

Fixed Pricing & Ordering Information

IPG generator models operate under fixed unit pricing structures. Standard options, voltage configurations, and delivery logistics are confirmed at order placement.

1. Electrical Configuration

Model-dependent voltage options (such as single-phase 230V or three-phase 400V systems), subject to final engineering confirmation for facility distribution requirements.

2. Enclosure Selection

Open chassis skid for indoor mechanical rooms, or weather-protective sound-attenuated canopies for exterior placement.

3. Switchgear & ATS

Manual transfer panels or automatic transfer switch (ATS) packages for seamless emergency transition.

4. Site & Logistics

Freight delivery logistics, crane placement accommodations, and startup commissioning requirements.

Ready to Place Your Order?

Submit your generator model selection and facility details. IPG sales engineering will prepare your official equipment invoice and payment instructions.

Engineering Guidance

How to Choose the Right Generator Capacity

A practical approach to sizing your IPG generator accurately based on verified electrical loads.

01

Total Running Load

Add together the steady-state continuous wattage demanded by all active electrical devices and lighting running concurrently during normal operational hours.

02

Starting & Surge Demands

Electric motors, induction pumps, and compressors draw momentary surge currents 2 to 3 times greater than steady-state ratings. Add adequate reserve headroom to handle these surges.

Interactive Load Calculator

Use our interactive sizing tool above to select your appliances, calculate running and surge watts, and find your recommended IPG capacity.

Load Assessment Protocol: Actual power requirements must be verified against equipment nameplates or calibrated electrical panel readings. IPG sales engineering is available to assist with facility load calculations.